Professional manufacturer in the design and production of glass-lined equipment for over 20 years!
+86-533-2775537 / 2777386
15953332144
Home > Products > Glass lined equipment > Glass lined reactor

    Closed Glass Lined Reactor

    • 型号F3000-30000L
    • 品牌DEWOJIN
    • 价格
    1. Detailed information
                                                                                                         Closed Glass Lined Reactor
            Our company's closed glass lined reactor is produced by making high content silica into high-quality corrosion-resistant enamel glaze, and spray the glaze on the surface of the metal matrix. The glaze will be closely adherent to the surface of the metal after a high-temperature firing of 950℃. Therefore, possessing the dual nature that combines the corrosion resistance of glass and the strength of metal, it is good corrosion resistant equipment. Now, it has been widely applied in industries and departments, such as petroleum, chemicals, light industries, medicines, agriculture, pharmaceuticals, foods, fuels, and scientific research. 
            Corrosion resistance of closed glass lined reactor: it is resistant to the corrosions of inorganic acids, organic acids, organic solvents and weak alkalis in all concentrations (except for hydrofluoric acids, media that contain fluoride ion, and concentrated phosphoric acids and strong alkalis with a concentration ≥30% and a temperature ≥180℃). 

                                                                            MetInfo enterprise content manager system | MetInfo CMS

                                                                     Closed Glass Lined Reactor (F Series Glass Lined Reactor)

                                                                                         Standard:HG/T2372-1992

                                                             MetInfo enterprise content manager system | MetInfo CMS                    MetInfo enterprise content manager system | MetInfo CMS

                                F3000-5000L                                             F10000-30000L

                           Nozzle Orientation                                       Nozzle Orientation

     

                                                  Overall Dimensions and Parameters of Closed Glass Lined Reactor

    Nominal
    volume
     L

    Actual
    volume
    L

    Heat exchange area of Jacket
    m2

    Model of Reducer

    Spec.of stuffing box. DN

    Spec of discharge valve
    DN

    Stirred speed 
    Rpm

     

    Anchor and frame

    Impeller
    /paddle

     
     

    F3000

    3100

    8.61

    BLD5.5-3

    95

    125

    /

    130

     

    F5000

    5050

    13.2

    BLD5.5-3

    95

    125

    /

    130

     

    F5000

    5050

    13.2

    BLD5.5-3

    95

    125

    /

    130

     

    F10000

    11670

    21.35

    BLD15-5

    110

    150

    /

    125

     

    F15000

    16450

    27.7

    BLD18.5-6

    160

    150

    /

    125

     

    F20000

    21790

    34.04

    BLD18.5-6

    160

    150

    /

    125

     

    F30000

    32610

    44.7

    BLD30-7

    160

    150

    /

    125

     

     

    Nominal
    volume
     L

    Sizes(mm)

    Approx
    Weight kg

    D

    D0

    D1

    D2

    D3

    D4

    H

    H1

    H2

    H3

    L

    h

    Anchor and frame

    Impeller
    /paddle

    F3000

    1600

    1120

    1750

    1964

    600

    /

    2290

    1200

    150

    1326

    4300

    /

    240

    3554

    F5000

    1600

    1120

    1750

    2050

    600

    /

    3290

    1200

    150

    1326

    5300

    /

    240

    4388

    F5000

    1750

    1200

    1900

    2150

    600

    /

    2935

    1200

    150

    1326

    5000

    /

    270

    5161

    F10000

    2200

    1540

    2400

    2734

    800

    /

    3668

    1420

    230

    2180

    6170

    /

    360

    8150

    F15000

    2400

    1680

    2600

    2940

    800

    /

    4326

    1400

    230

    2180

    7280

    /

    360

    11970

    F20000

    2600

    1820

    2800

    /

    900

    2000

    4776

    /

    250

    2180

    7710

    /

    400

    15000

    F30000

    3000

    2100

    3200

    /

    1100

    2100

    5575

    /

    280

    2200

    8360

    /

    450

    20700

     

                                            Nozzle Sizes Table of Closed Glass Lined Reactor

    Nominal
    volume L

    a

    b

    c

    d

    e

    f

    g

    h

    k

    m

    Discharge

    Inlet/Outlet

    Vent

    F3000 F5000(φ1600)

    300×400

    125

    100

    100

    125

    125

    100

    125

    125

    5-70

    1/2"

    F5000 φ1750

    300×400

    125

    125

    125

    125

    150

    125

    150

    125

    6-70

    1/2"

    F10000

    300×400

    200

    150

    150

    150

    150

    125

    150

    150

    125

    150

    4-80 3-70

    3/4"

    F15000

    450

    250

    150

    150

    150

    150

    125

    150

    150

    125

    150

    7-100

    3/4"

    F20000

    450

    250

    150

    150

    150

    150

    125

    150

    150

    125

    150

    7-100

    3/4"

    F30000

    450

    250

    150

    150

    150

    150

    125

    150

    150

    125

    150

    7-125

    3/4"

     

                                                          Main Technical Performance of Closed Glass Lined Reactor

    F series glass lined reactor

    Max.Operation pressure (Mpa)

    Opertion temperature °C

    Thickness of Glass lining
    mm

     

    High voltage test to glass lining layer
    kv

    Inside of vessel

     

    Inside of jacket

     

    Inside of vessel

     

    Inside of jacket 

     

    Stuffing box

     

    Single face mechanical seal

     

    Double-face mechanical seal

     

    0.6

    0~200

    0~200

    0.8~2.0

    20 (Retest of User:6)

    0.25

    0.4

    0.6~1.0

    Remark

    1. Note: when the working pressure in the tank is over 0.4Mpa or the working temperature is lower than 0, then all these should be indicated clearly when the user places an order.

    2. Temperature difference operation limit for glass lining: cooling shock:110oCthermo shock:120oC.(This is Destructive Test)